Rating:
82026
{0}%
No votes cast
Anderson Ranch Dam Spillway Bridge
Facts
- Overview
- Concrete tee beam bridge over Anderson Ranch Dam Spwy on Maintenance Road
- Location
- Elmore County, Idaho
- Status
- Open to traffic
- History
- Built 1950
- Design
- Concrete tee beam
- Dimensions
-
Length of largest span: 24.9 ft.
Total length: 55.1 ft.
Deck width: 24.9 ft.
- Approximate latitude, longitude
- +43.35764, -115.44919 (decimal degrees)
43°21'28" N, 115°26'57" W (degrees°minutes'seconds")
- Approximate UTM coordinates
- 11/625669/4801699 (zone/easting/northing)
- Average daily traffic (as of 2017)
- 40
- Inventory number
- BH 82026 (Bridgehunter.com ID)
- Inspection report (as of August 2017)
- Overall condition: Good
Superstructure condition rating: Good (7 out of 9)
Substructure condition rating: Good (7 out of 9)
Deck condition rating: Good (7 out of 9)
Sufficiency rating: 92.3 (out of 100)
View more at BridgeReports.com
Update Log
- June 30, 2018: Added by Dana and Kay Klein