Rating:
No votes cast

Southern Outlet Drain Bridge

Map 

Facts 

Overview
Steel stringer bridge over Southern Outlet Drai on TR 486
Location
Hamilton County, Illinois
Status
Open to traffic
History
Built 1909
Design
Steel stringer
Dimensions
Length of largest span: 67.9 ft.
Total length: 69.9 ft.
Deck width: 19.7 ft.
Approximate latitude, longitude
+38.20525, -88.38961   (decimal degrees)
38°12'19" N, 88°23'23" W   (degrees°minutes'seconds")
Approximate UTM coordinates
16/378333/4229500 (zone/easting/northing)
Quadrangle map:
Bungay
Inventory number
BH 70796 (Bridgehunter.com ID)
Inspection (as of 02/2015)
Deck condition rating: Fair (5 out of 9)
Superstructure condition rating: Satisfactory (6 out of 9)
Substructure condition rating: Poor (4 out of 9)
Appraisal: Structurally deficient
Sufficiency rating: 40.5 (out of 100)
Average daily traffic (as of 2012)
25

Update Log 

  • February 6, 2016: Added by Elliott Johnson

Sources 

  • Elliott Johnson - elliottsgon15 [at] hotmail [dot] com